Lumina Lighting Design Suite
Projects New design Fixtures Criteria Reference Docs Sign in Create an account

Tutorial 3 — Classroom

Lumina walkthrough · TUT-03 · revision 1 · Berlin

Tutorial project, kept read-only as a reference. Duplicate it to make changes.
A 9 x 7 m classroom at 300 lx with a separately lit whiteboard wall. Shows task zones, cylindrical illuminance for face lighting, and glare control from the pupils' viewing directions.

Project totals

All assessed criteria met
Rooms

1

63.0 m² total
Luminaires

6

240 W installed
Power density

3.81W/m²

Annual energy

538kWh

Annual cost

€140

Annual carbon

204kg

CO₂e

Rooms

1
RoomActivity SizeLuminaires EavgUo UGRLPD ComplianceActions
Classroom Classrooms and tutorial rooms
300 lx target
9.0×7.0×3.0 6 432 lx 0.817 18.8 3.81 compliant

Project settings

Operating schedule

School

Drives the annual energy figure. Hours are fractions of the installed load, so a background level outside working hours is modelled rather than ignored.

Hour01234567891011121314151617181920212223
Weekday 5 5 5 5 5 5 5 5 100 100 100 100 100 100 100 100 100 5 5 5 5 5 5 5

Version history

1
RevLabelSavedSize
1 Seeded tutorial 2026-09-26 11:57 1.0 KB