Tutorial 1 — Open plan office

Lumina walkthrough · TUT-01 · revision 1 · London

Tutorial project, kept read-only as a reference. Duplicate it to make changes.
A 12 x 9 m open plan office at 500 lx to EN 12464-1, lit with recessed LED panels on a regular grid. Start here: it shows the whole workflow from space setup to a compliance report.

Project totals

All assessed criteria met
Rooms

1

108.0 m² total
Luminaires

16

512 W installed
Power density

4.74W/m²

Annual energy

934kWh

Annual cost

£234

Annual carbon

193kg

CO₂e

Rooms

1
RoomActivity SizeLuminaires EavgUo UGRLPD ComplianceActions
Open plan office Open plan office, general
500 lx target
12.0×9.0×2.9 16 537 lx 0.892 17.3 4.74 compliant

Project settings

Operating schedule

Office

Drives the annual energy figure. Hours are fractions of the installed load, so a background level outside working hours is modelled rather than ignored.

Hour01234567891011121314151617181920212223
Weekday 10 10 10 10 10 10 10 100 100 100 100 100 100 100 100 100 100 100 100 10 10 10 10 10