Lumina Lighting Design Suite
Projects New design Fixtures Criteria Reference Docs Sign in Create an account

Generic LED High Bay 100W 15000lm 90deg

HB-100-90 · highbay · LED · version 1

Download IES
Catalogue entry. Its intensity distribution is a model generated from a physical shape function, normalised so integrated flux equals the stated output. Import the manufacturer's photometric file before issuing a design.

Intensity distribution

Polar intensity diagram in the C0-C180 and C90-C270 planes
Integrated flux
15 000 lm
Downward / upward
15 000 / 0 lm
Downward fraction
100.0% — direct
Peak intensity
7 327 cd at 0° from nadir
Beam angle
89.0°
Field angle
141.0°
Cut-off
90° highest tabulated vertical angle
Table
37 vertical × 1 C planes, axial symmetry, type C
Efficacy from the file
150.0 lm/W

Product data

Rated output
15 000 lm
Input power
100.0 W
Efficacy
150.0 lm/W
Colour temperature
5000 K
Colour rendering
Ra 80
Glare class
—
Ingress protection
IP65
Dimensions
350 × 350 × 120 mm
Dimmable
yes
Rated life
70 000 h
Unit cost
$135.00
Applications
industrial,warehouse,sports

Light loss factors

Their product is the maintenance factor contribution of this product. The room's own maintenance factor overrides it unless you choose to derive it per fixture.

Lamp lumen maintenance
0.950
Luminaire dirt depreciation
0.950
Room surface dirt
0.980
Lamp survival
1.000
Product LLF
0.8845
Generic product with a model intensity distribution. Import the manufacturer IES or LDT file before issuing a design.

Zonal lumen distribution

Flux emitted into each 10° band of vertical angle, measured from nadir. This is the classic zonal lumen table and is what determines how much light reaches the working plane versus the walls and ceiling.

ZoneLumensShareProfile
0–10° 688.6 4.59%
10–20° 1 922.7 12.82%
20–30° 2 762.5 18.42%
30–40° 3 050.8 20.34%
40–50° 2 769.1 18.46%
50–60° 2 061.7 13.74%
60–70° 1 200.4 8.00%
70–80° 472.9 3.15%
80–90° 71.1 0.47%

Version history

VersionChangeByWhen
1 Seeded from the starter library system 2026-09-26 11:57
Photometric file, as stored
File name
led-high-bay-100w-15000lm-90deg.ies
Format
IES
Checksum
c46f6b012fa464520697ad6d13f1c334…
Imported
2026-09-26 11:57
IESNA:LM-63-2002
[TEST] Lumina synthetic
[TESTLAB] Lumina
[MANUFAC] Generic
[LUMINAIRE] LED High Bay 100W 15000lm 90deg
[ISSUEDATE] 2026-09-26
[LUMCAT] HB-100-90
[LAMP] LED
[OTHER] Model distribution generated by Lumina. Not measured photometry.
TILT=NONE
1 15000.0 1.0 37 1 1 2 0.350 0.350 0.120
1.0 1.0 100.00
0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0 37.5 40.0 42.5 45.0 47.5 50.0 52.5 55.0 57.5
60.0 62.5 65.0 67.5 70.0 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0
0.0
7326.91 7312.97 7271.25 7202.07 7105.95 6983.56 6835.79 6663.64 6468.27 6250.96 6013.13 5756.34 5482.30 5192.89 4890.17
4576.42 4254.12 3925.94 3594.76 3263.59 2935.54 2613.73 2301.24 2001.02 1715.81 1448.05 1199.85 972.91 768.57 587.74
431.01 298.65 190.70 107.05 47.50 11.86 0.00