Generic LED Cove Uplight 1000 1800lm
COVE-1000 · linear · LED · version 1
Catalogue entry. Its intensity distribution is a model generated from a physical shape
function, normalised so integrated flux equals the stated output. Import the manufacturer's
photometric file before issuing a design.
Intensity distribution
- Integrated flux
- 1 800 lm
- Downward / upward
- 0 / 1 800 lm
- Downward fraction
- 0.0% — indirect
- Peak intensity
- 573 cd at 180° from nadir
- Beam angle
- not defined (the peak sits off axis)
- Field angle
- —
- Cut-off
- 180° highest tabulated vertical angle
- Table
- 37 vertical × 1 C planes, axial symmetry, type C
- Efficacy from the file
- 120.0 lm/W
Product data
- Rated output
- 1 800 lm
- Input power
- 15.0 W
- Efficacy
- 120.0 lm/W
- Colour temperature
- 3000 K
- Colour rendering
- Ra 90
- Glare class
- —
- Ingress protection
- IP20
- Dimensions
- 1 000 × 50 × 50 mm
- Dimmable
- yes
- Rated life
- 50 000 h
- Unit cost
- $62.00
- Applications
- hospitality,retail,residential
Light loss factors
Their product is the maintenance factor contribution of this product. The room's own maintenance factor overrides it unless you choose to derive it per fixture.
- Lamp lumen maintenance
- 0.950
- Luminaire dirt depreciation
- 0.910
- Room surface dirt
- 0.980
- Lamp survival
- 1.000
- Product LLF
- 0.8472
Generic product with a model intensity distribution. Import the manufacturer IES or LDT file before issuing a design.
Zonal lumen distribution
Flux emitted into each 10° band of vertical angle, measured from nadir. This is the classic zonal lumen table and is what determines how much light reaches the working plane versus the walls and ceiling.
| Zone | Lumens | Share | Profile |
|---|---|---|---|
| 90–100° | 54.3 | 3.02% |
|
| 100–110° | 156.3 | 8.68% |
|
| 110–120° | 239.4 | 13.30% |
|
| 120–130° | 293.7 | 16.32% |
|
| 130–140° | 312.6 | 17.36% |
|
| 140–150° | 293.7 | 16.32% |
|
| 150–160° | 239.4 | 13.30% |
|
| 160–170° | 156.3 | 8.68% |
|
| 170–180° | 54.3 | 3.02% |
|
Version history
| Version | Change | By | When |
|---|---|---|---|
| 1 | Seeded from the starter library | system | 2026-09-26 11:57 |
Photometric file, as stored
- File name
- led-cove-uplight-1000-1800lm.ies
- Format
- IES
- Checksum
- 13d2c9d2d2f3581f1af72f9c62368b1f…
- Imported
- 2026-09-26 11:57
IESNA:LM-63-2002
[TEST] Lumina synthetic
[TESTLAB] Lumina
[MANUFAC] Generic
[LUMINAIRE] LED Cove Uplight 1000 1800lm
[ISSUEDATE] 2026-09-26
[LUMCAT] COVE-1000
[LAMP] LED
[OTHER] Model distribution generated by Lumina. Not measured photometry.
TILT=NONE
1 1800.0 1.0 37 1 1 2 0.050 1.000 0.050
1.0 1.0 15.00
90.0 92.5 95.0 97.5 100.0 102.5 105.0 107.5 110.0 112.5 115.0 117.5 120.0 122.5 125.0 127.5 130.0 132.5 135.0 137.5
140.0 142.5 145.0 147.5 150.0 152.5 155.0 157.5 160.0 162.5 165.0 167.5 170.0 172.5 175.0 177.5 180.0
0.0
0.00 24.99 49.94 74.79 99.50 124.02 148.31 172.31 195.98 219.28 242.17 264.59 286.51 307.88 328.67 348.83 368.33 387.12
405.18 422.47 438.96 454.60 469.39 483.28 496.25 508.27 519.33 529.40 538.46 546.50 553.49 559.43 564.31 568.11 570.84
572.47 573.02